Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector

Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector

Merknaam: XHA
Modelnummer: KF715UVIR2
Moq: 1PCS
Prijs: negotiable
Verpakking: 8pcs/Carton
Betalingsvoorwaarden: T/T, Western Union
Gedetailleerde informatie
Place of Origin:
China
Certificering:
CCC
Detection Range:
1-40 meters
Response Time:
Less than 10 seconds
Mounting Type:
Ceiling or wall mounted
Power Supply:
24VDC
Alarm Output:
Relay output
Humidity Range:
0-95% non-condensing
Fire response time:
≤10S
Type:
Infrared Flame Detector
Operating Temperature:
-10°C to 55°C
Supply Ability:
500pcs/month
Productbeschrijving

Explosion Proof High-Performance Infrared Flame Detector For Transportation And Storage Facilities


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 0

Introduction
 

Infrared (IR) flame detectors are specialized sensors designed to detect the presence of flames by identifying the unique infrared light signature produced by combustion. These devices are widely used in industrial and commercial applications to provide early warning of potential fire hazards.

The primary working principle of an IR flame detector involves monitoring the infrared radiation emitted by flames. Flames generated by the combustion of various fuels, including hydrocarbon-based materials, produce a characteristic infrared radiation spectrum that can be detected by the sensor. This allows the detector to distinguish the infrared signature of a flame from other heat sources or ambient infrared radiation.



Suitable places


1. Transportation, storage, production and other places for flammable goods;
2. Substation facilities, engine room, power station environments;
3. Places where open flames are strictly prohibited, such as liquefied gas stations, garages, gas stations, etc
4. Harsh environment and other environment where the other kind detectors are difficult to function.



Specifications




Working voltage 18V-32VDC
Interface 4”(Φ20mm) explosion-proof hose
Infrared Flame Detector Detection Angle 90 degree
Level of protection IP66/IP65
Explosion Proof Level Ex d lIC T6 Gb. Ex tD A21 IP66/IP67 T80℃
Alarm Status ≤40mA/24VDC
Fire response time ≤10S
Sensitivity 1m-40m can respond(0.1 m-1.3m)
Working environment humidity ≤95%RH, no condensation


 

Instruction


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 1


The green work indicator is steady on at the normal situation.
when the fire is found, The red alarm indicator is steady on. At the same time, the fire alarm relay is closed and the yellow/white lines are conductive, output the fire alarm signal.
The detector is a non-coding detector, which needs to connect the interface module when it is connected to the bus system.


Wiring Instruction


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 2


Red/black: 24V power line
Yellow/white:Alarm relay ouput, it is closed, normally open.
Blue/green:Fault relay output, it’s open, normally closed.
Maintenance:
In order to keep in good work situation, it need arrange test to the flame detector every 3 months at least. Once the detector is damaged or not working properly, need to repaire or replace accordingly.


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 3


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 10 working days lead time.

5. Welcome sample order.
 





Goede prijs.  online

Details Van De Producten

Thuis > Producten >
Brandmelder Vlammelder
>
Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector

Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector

Merknaam: XHA
Modelnummer: KF715UVIR2
Moq: 1PCS
Prijs: negotiable
Verpakking: 8pcs/Carton
Betalingsvoorwaarden: T/T, Western Union
Gedetailleerde informatie
Place of Origin:
China
Merknaam:
XHA
Certificering:
CCC
Model Number:
KF715UVIR2
Detection Range:
1-40 meters
Response Time:
Less than 10 seconds
Mounting Type:
Ceiling or wall mounted
Power Supply:
24VDC
Alarm Output:
Relay output
Humidity Range:
0-95% non-condensing
Fire response time:
≤10S
Type:
Infrared Flame Detector
Operating Temperature:
-10°C to 55°C
Minimum Order Quantity:
1PCS
Prijs:
negotiable
Packaging Details:
8pcs/Carton
Delivery Time:
3 Working days
Payment Terms:
T/T, Western Union
Supply Ability:
500pcs/month
Productbeschrijving

Explosion Proof High-Performance Infrared Flame Detector For Transportation And Storage Facilities


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 0

Introduction
 

Infrared (IR) flame detectors are specialized sensors designed to detect the presence of flames by identifying the unique infrared light signature produced by combustion. These devices are widely used in industrial and commercial applications to provide early warning of potential fire hazards.

The primary working principle of an IR flame detector involves monitoring the infrared radiation emitted by flames. Flames generated by the combustion of various fuels, including hydrocarbon-based materials, produce a characteristic infrared radiation spectrum that can be detected by the sensor. This allows the detector to distinguish the infrared signature of a flame from other heat sources or ambient infrared radiation.



Suitable places


1. Transportation, storage, production and other places for flammable goods;
2. Substation facilities, engine room, power station environments;
3. Places where open flames are strictly prohibited, such as liquefied gas stations, garages, gas stations, etc
4. Harsh environment and other environment where the other kind detectors are difficult to function.



Specifications




Working voltage 18V-32VDC
Interface 4”(Φ20mm) explosion-proof hose
Infrared Flame Detector Detection Angle 90 degree
Level of protection IP66/IP65
Explosion Proof Level Ex d lIC T6 Gb. Ex tD A21 IP66/IP67 T80℃
Alarm Status ≤40mA/24VDC
Fire response time ≤10S
Sensitivity 1m-40m can respond(0.1 m-1.3m)
Working environment humidity ≤95%RH, no condensation


 

Instruction


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 1


The green work indicator is steady on at the normal situation.
when the fire is found, The red alarm indicator is steady on. At the same time, the fire alarm relay is closed and the yellow/white lines are conductive, output the fire alarm signal.
The detector is a non-coding detector, which needs to connect the interface module when it is connected to the bus system.


Wiring Instruction


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 2


Red/black: 24V power line
Yellow/white:Alarm relay ouput, it is closed, normally open.
Blue/green:Fault relay output, it’s open, normally closed.
Maintenance:
In order to keep in good work situation, it need arrange test to the flame detector every 3 months at least. Once the detector is damaged or not working properly, need to repaire or replace accordingly.


Infrared Flame Detector Fire Alarm Flame Detector for Industrial Fire Safety Needs Explosion Proof Flame Detector 3


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 10 working days lead time.

5. Welcome sample order.